Hardware  >   Cooling Equipment  >  

Split Systems

RSS Feed    Add to Google    Add to My Yahoo!
Split Systems White Papers (View All Report Types)
 
The Different Types of Air Conditioning Equipment for IT Environments
sponsored by APC by Schneider Electric
WHITE PAPER: Cooling equipment for an IT environment can be implemented in 10 basic configurations. The information in this paper allows IT professionals to be more involved in the specification of precision cooling solutions that better align with IT objectives.
Posted: 13 Jul 2009 | Published: 09 Jul 2009

APC by Schneider Electric

Cooling Cost-Saving Strategies: Comfort Cooling vs. Precision Cooling
sponsored by Emerson Network Power
WHITE PAPER: Important differences exist between precision cooling and building air conditioning (comfort cooling) in controlling these environmental conditions. In this paper, we compare both cooling systems’ ability to maintain favorable environmental conditions, and their energy efficiency and annual operating costs.
Posted: 11 Oct 2010 | Published: 11 Oct 2010

Emerson Network Power

Energy Efficient Cooling for Data Centers: A Close-Coupled Row Solution
sponsored by Schneider Electric
WHITE PAPER: The trend of increasing heat densities in data centers has held consistent with advances in computing technology for many years. As power density increased, it became evident that the degree of difficulty in cooling these higher power demand loads was also increasing.
Posted: 01 Oct 2010 | Published: 01 Oct 2010

Schneider Electric

Battery Technology Data Centers and Network Rooms: Lead-Acid Battery Options
sponsored by APC by Schneider Electric
WHITE PAPER: This paper discusses the advantages and disadvantages of Flooded, Valve Regulated Lead Acid (VLRA), and Modular Battery Catridge (MBC) lead-acid battery technologies.
Posted: 04 Feb 2009 | Published: 04 Feb 2009

APC by Schneider Electric

Fundamental Principles of Air Conditioners for Information Technology
sponsored by APC by Schneider Electric
WHITE PAPER: Every Information Technology professional who is responsible for the operation of computing equipment needs to understand the function of air conditioning in the data center or network room. This introductory paper explains the function of basic components of an air conditioning system for a computer room.
Posted: 01 Apr 2010 | Published: 01 Jan 2004

APC by Schneider Electric

Air Distribution Architecture Options for Mission Critical Facilities
sponsored by APC by Schneider Electric
WHITE PAPER: An understanding of the 9 types of cooling systems and their attributes can be used to develop guidelines for when each type should be used, and such guidelines are provided in this paper for both raised floor and hard floor applications.
Posted: 01 Apr 2010 | Published: 20 Nov 2008

APC by Schneider Electric

Energy Impact of Increased Server Inlet Temperature
sponsored by APC by Schneider Electric
WHITE PAPER: The quest for efficiency improvement raises questions regarding the optimal air temperature for data centers. The goal is to find the optimal temperature range where the combined IT and cooling load is minimized. Data presented is based upon actual sealed testing of different cooling systems when subjected to the simulated composite server...
Posted: 13 Jul 2009 | Published: 09 Jul 2009

APC by Schneider Electric

Power and Cooling for VoIP and IP Telephony Applications
sponsored by APC by Schneider Electric
WHITE PAPER: This paper explains how to plan for VoIP power and cooling needs, and describes simple, fast, reliable, and cost effective strategies for upgrading old facilities and building new facilities.
Posted: 04 Jun 2007 | Published: 01 Feb 2005

APC by Schneider Electric

Monitoring the Computer Room's Physical Environment
sponsored by Sensaphone
WHITE PAPER: This paper addresses the greatest environmental threats to the functionality of small to medium computer rooms and presents the time and cost savings associated with the integration of a remote monitoring system.
Posted: 22 Apr 2008 | Published: 22 Apr 2008

Sensaphone

Calculating Total Cooling Requirements for Data Centers
sponsored by APC by Schneider Electric
WHITE PAPER: This white paper describes how to estimate heat output from IT equipment and other devices in a data center such as UPS, for purposes of sizing air conditioning systems.
Posted: 10 Jul 2009 | Published: 09 Jul 2009

APC by Schneider Electric
 
 
Visit WhatIs.com - a knowledge exploration and self-education tool about information technology.
Home | About Us | Contact Us | Advertise with Us | Partner with Us | Site Index
TechTarget provides enterprise IT professionals with the information they need to perform their jobs - from developing strategy, to making cost-effective IT purchase decisions and managing their organizations' IT projects - with its network of technology-specific Web sites, events and magazines

Definitions: A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Other   TechTarget - The Most Targeted IT Media
TechTarget Corporate Web Site  |   Media Kits  




All Rights Reserved, Copyright 2000 - 2013, TechTarget | Read our Privacy Statement