Identifying opportunities for resellers in virtualised business
| sponsored by APC by Schneider Electric
EGUIDE:Access this e-guide to discover how resellers can take advantage of the growing virtualisation market. Explore topics like managing the complexities of virutalisation projects and delivering real expertise for virtual business. Posted: 20 Apr 2012 | Published: 20 Apr 2012
|
|
|
Transcript: Cut Costs and Improve Planning with Data Center Infrastructure Management Software
| sponsored by APC by Schneider Electric
WHITE PAPER:Access this essential resource to discover how data centre infrastructure management tools can help with daily maintenance operations, data analytics, planning and much more – all while driving down your bottom line. Posted: 20 Apr 2012 | Published: 20 Apr 2012
|
|
|
Data Center Facilities Design for IT Chapter 1: Communication Strategies for Data Center Designs
| sponsored by APC by Schneider Electric
EBOOK:This expert e-book explores how effective communication between IT and facilities can improve your organization's bottom line and maximize data center efficiency. Posted: 03 Apr 2012 | Published: 03 Apr 2012
|
|
|
The Different Technologies for Cooling Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:Inside, explore 13 cooling technologies and their components designed to transport heat energy from the IT environment to the outside atmosphere. Use this as a foundation to successfully manage the specification, installation, and operation of IT environment cooling systems. Posted: 27 Mar 2012 | Published: 27 Mar 2012
|
|
|
Data Center Projects: Advantages of Using a Reference Design
| sponsored by APC by Schneider Electric
WHITE PAPER:Inside, discover how you can adopt a well conceived reference design to improve any data center project, as well as data center operations. Learn how to simplify and shorten the planning and implementation process and reduce downtime risks once up and running. Explore reference designs and their benefits. Posted: 27 Mar 2012 | Published: 27 Mar 2012
|
|
|
High Efficiency Economizer-based Cooling Modules for Large Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:Access this resource to explore a new approach to data center cooling that uses approximately half the energy of traditional methods, while improving scalability, availability, ease of maintenance, and more. Posted: 27 Mar 2012 | Published: 27 Mar 2012
|
|
|
Comparing Availability of Various Rack Power Redundancy Configurations
| sponsored by APC by Schneider Electric
WHITE PAPER:This resource explores the various electrical architectures for redundancy present in today’s mission-critical environments. Posted: 27 Mar 2012 | Published: 27 Mar 2012
|
|
|
Top 10 Mistakes in Data Center Operations: Operating Efficient and Effective Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:Access this resource to explore the top ten mistakes that are usually present in data center operations. Posted: 23 Mar 2012 | Published: 23 Mar 2012
|
|
|
Cut Costs and Improve Planning with Data Centre Infrastructure Management Software
| sponsored by APC by Schneider Electric
WEBCAST:This talk covers, through a series of examples, how data centre infrastructure management (DCIM) software tools can simplify operational processes, cut costs, and speed up information delivery. Posted: 20 Mar 2012 | Premiered: Mar 20, 2012
|
|
|
Virtualization and Cloud Computing: Optimized Power, Cooling, and Management Maximizes Benefits
| sponsored by APC by Schneider Electric
WHITE PAPER:Virtualization can have major consequences on the data center physical infrastructure (DCPI). Higher power densities can challenge the cooling capabilities of an existing system. Reduced energy consumption may actually worsen the data center's power usage effectiveness (PUE). Learn more about the particular effects of virtualization inside. Posted: 09 Nov 2011 | Published: 09 Nov 2011
|
|
|
Impact of Hot and Cold Aisle Containment on Data Center Temperature and Efficiency
| sponsored by APC by Schneider Electric
WHITE PAPER:This resource examines hot-air and cold-air containment methodologies and highlights the reasons why hot-aisle containment is the preferred best practice for new data centres. Posted: 09 Nov 2011 | Published: 09 Nov 2011
|
|
|
Guidance for Calculation of Efficiency (PUE) in Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:The efficiency ratings of a data centre can vary substantially depending on what methodologies are used. This paper discusses the importance of measuring data centre efficiency and explores the issues companies face when establishing the PUE of an infrastructure. Posted: 09 Nov 2011 | Published: 09 Nov 2011
|
|
|
How Data Centre Infrastructure Management Software Improves Planning and Cuts Operational Costs
| sponsored by APC by Schneider Electric
WHITE PAPER:Access this exclusive resource to learn how data centre infrastructure management software tools can simplify operational processes, reduce costs, and accelerate information delivery. Posted: 29 Jun 2011 | Published: 29 Jun 2011
|
|
|
The Advantages of Row and Rack-Oriented Cooling Architectures for Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:This paper contrasts room, row and rack architectures and shows why row-oriented cooling will emerge as the preferred solution for most next generation data centers. Posted: 01 Oct 2010 | Published: 01 Oct 2010
|
|
|
Cooling Strategies for IT Wiring Closets and Small Rooms
| sponsored by APC by Schneider Electric
WHITE PAPER:This paper describes the science and practical application of an improved method for the specification of cooling for wiring closets. Posted: 01 Oct 2010 | Published: 01 Oct 2010
|
|
|
Determining Total Cost of Ownership for Data Center and Network Room Infrastructure
| sponsored by APC by Schneider Electric
WHITE PAPER:This white paper describes an improved method for measuring TCO for data center and network room physical infrastructure, and provides examples on how to relate these costs to the overall IT infrastructure and evaluate cost control strategies. Posted: 01 Apr 2010 | Published: 01 Feb 2005
|
|
|
Deploying High-Density Pods in a Low-Density Data Center
| sponsored by APC by Schneider Electric
WHITE PAPER:This white paper details how self-contained high-density zones enable a reliable operation of high-density equipment without impacting a low-density data center. Posted: 27 Jan 2010 | Published: 01 Oct 2010
|
|
|
Identifying and Fixing Data Center Hot Spots
| sponsored by APC by Schneider Electric
WEBCAST:
Hot spots can seriously reduce the efficiency of an organization's computer equipment. Watch this webcast for expert tips on remediating your data center's hot spots and discover the costs associated with the task.
Posted: 21 Aug 2009 | Premiered: Aug 21, 2009
|
|
|
Power and Cooling Capacity Management for Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:This paper describes the principles for achieving power and cooling capacity management. Posted: 10 Jul 2009 | Published: 01 Jan 2007
|
|
|
Cooling Strategies for Ultra-High Density Racks and Blade Servers
| sponsored by APC by Schneider Electric
WHITE PAPER:This white paper addresses common data center cooling challenges and describes five strategies for deploying ultra-high power racks, with practical solutions for both new and existing data centers. Posted: 29 Apr 2009 | Published: 01 Oct 2010
|
|
|
Implementing Energy Efficient Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:Electricity usage costs have become an increasing fraction of the total cost of running a data centers. This paper explains how achieve electricity savings and provides examples of methods that can greatly reduce electrical power consumption. Posted: 29 Apr 2009 | Published: 01 Dec 2006
|
|
|
Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms
| sponsored by APC by Schneider Electric
WHITE PAPER:Access this exclusive resource to learn how to avoid mistakes when installing cooling systems and racks in data centers or network rooms. This paper examines these typical mistakes, explains their principles, quantifies their impacts, and describes simple remedies. Posted: 29 Apr 2009 | Published: 01 Dec 2003
|
|
|
Standardization and Modularity in Network-Critical Physical Infrastructure
| sponsored by APC by Schneider Electric
WHITE PAPER:
Standardization and its close relative, modularity, create wide-ranging benefits in NCPI that streamline and simplify every process from initial planning to daily operation.
Posted: 04 Feb 2009 | Published: 04 Feb 2009
|
|
|
AC vs DC Power Distribution for Data Centers
| sponsored by APC by Schneider Electric
WHITE PAPER:In this paper, you'll learn why high-efficiency AC will likely emerge as the dominant choice for data center power distribution. Topics covered include a review of the characteristics of AC & DC distribution, A mathematical model of the efficiency of two different AC distribution systems, and Why many of the DC benefits are unfounded. Posted: 10 Jul 2008 | Published: 01 Oct 2010
|
|
|
Server, Network and Telecom Power Solutions: Symmetra®Power Array™
| sponsored by APC by Schneider Electric
BROCHURE:Symmetra Power Array was designed to fit all these customer expectations. It the world's first redundant, scalable, user-serviceable, and manageable power protection solution. Posted: 25 Jan 2004 | Published: 01 Jan 2004
|
|
|